Rabbit anti-Human EpCAM Monoclonal Antibody | anti-EpCAM antibody
Recombinant Anti-EpCAM Antibody, Rabbit Monoclonal
No cross-reactivity in ELISA with Human CD146/MCAM, Human CD171/N-CAML1/L1CAM, Human OBCAM/OPCML, Human TROP2/TACSTD2
ELISA: 1:25,000-1:50,000
IHC-P: 1:1000-1:5000
ICC/IF: 1:250-1:5000
FC/FACS/FCM: 1:100-1:500
IP: 0.2-1uL/mg of lysate
ELISA (Det): 1:5000-1:50,000
ELISA (Det): This antibody will detect Human EpCAM/TROP-1/TACSTD1 in ELISA pair set.
In a sandwich ELISA, it can be used as detection antibody when paired with.
IP (Immunoprecipitation)
(EpCAM was immunoprecipitated using:Lane A:0.5 mg MCF-7 Whole Cell LysateLane B:0.5 mg A431 Whole Cell LysateLane C:0.5 mg HepG2 Whole Cell LysateLane D:0.5 mg Caco-2 Whole Cell Lysate0.5 uL anti-EpCAM rabbit monoclonal antibody and 15 ul of 50 % Protein G agarose.Primary antibody:Anti-EpCAM rabbit monoclonal antibody,at 1:5000 dilution Secondary antibody:Dylight 800-labeled antibody to rabbit IgG (H+L), at 1:5000 dilution Developed using the odssey technique.Performed under reducing conditions.Predicted band size: 40 kDaObserved band size: 40 kDa)
WB (Western Blot)
(Anti-EpCAM rabbit monoclonal antibody at 1:500 dilutionLane A: MCF-7 Whole Cell LysateLysates/proteins at 30 ug per lane.SecondaryGoat Anti-Rabbit IgG H&L (Dylight800) at 1/10000 dilution.Developed using the Odyssey technique. Performed under reducing conditions.Predicted band size:34 kDaObserved band size:38 kDa)
FCM (Flow Cytometry)
(Flow cytometric analysis of anti-EpCAM (CD326) reactivity on SKBR3 cells. SKBR3 cells were stained with anti-EpCAM (CD326) Monoclonal Ab (10694-R028), then a FITC-conjugated second step antibody. The histogram were derived from the gated events based on light scattering characteristics of viable cells.)
IHC (Immunohistochemistry)
(Immunochemical staining of human EpCAM in human bladder carcinoma with rabbit monoclonal antibody at 1:2500 dilution, formalin-fixed paraffin embedded sections. Positive staining was localized to membrane of transitional epithelium.)
IHC (Immunohistochemistry)
(Immunochemical staining of human EpCAM in human colon carcinoma with rabbit monoclonal antibody at 1:2500 dilution, formalin-fixed paraffin embedded sections. Positive staining was localized to membrane of colonic gland epithelium.)
IF (Immunofluorescence)
(Immunofluorescence staining of Human EpCAM in SKBR3 cells. Cells were fixed with 4% PFA, blocked with 10% serum, and incubated with Rabbit anti-Human EpCAM monoclonal antibody (1:500) at 4 degree C overnight. Then cells were stained with the Alexa Fluor 488-conjugated Goat Anti-rabbit IgG secondary antibody (green) and counterstained with DAPI (blue). Positive staining was localized to plasma membrane.)
Trzpis M, et al. (2008) EpCAM in morphogenesis. Front Biosci. 13: 5050-5.
Munz M, et al. (2009) The emerging role of EpCAM in cancer and stem cell signaling. Cancer Res. 69(14): 5627-9.
Carpenter G, et al. (2009) EpCAM: another surface-to-nucleus missile. Cancer Cell. 15(3): 165-6.
NCBI and Uniprot Product Information
Similar Products
Product Notes
The EpCAM epcam (Catalog #AAA27736) is an Antibody produced from Rabbit and is intended for research purposes only. The product is available for immediate purchase. The Recombinant Anti-EpCAM Antibody, Rabbit Monoclonal reacts with Human and may cross-react with other species as described in the data sheet. AAA Biotech's EpCAM can be used in a range of immunoassay formats including, but not limited to, Western Blot (WB), ELISA (EIA), ELISA (EIA) (Det), Immunohistochemistry-Paraffin (IHC-P), Flow Cytometry (FC/FACS/FCM), Immunocytochemistry (ICC), Immunofluorescence (IF), Immunoprecipitation (IP). WB: 1:500-1:1000 ELISA: 1:25,000-1:50,000 IHC-P: 1:1000-1:5000 ICC/IF: 1:250-1:5000 FC/FACS/FCM: 1:100-1:500 IP: 0.2-1uL/mg of lysate ELISA (Det): 1:5000-1:50,000 ELISA (Det): This antibody will detect Human EpCAM/TROP-1/TACSTD1 in ELISA pair set. In a sandwich ELISA, it can be used as detection antibody when paired with. Researchers should empirically determine the suitability of the EpCAM epcam for an application not listed in the data sheet. Researchers commonly develop new applications and it is an integral, important part of the investigative research process. It is sometimes possible for the material contained within the vial of "EpCAM, Monoclonal Antibody" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.Precautions
All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.Disclaimer
Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.Item has been added to Shopping Cart
If you are ready to order, navigate to Shopping Cart and get ready to checkout.