Mitochondrial Permeability Transition Pore Assay Kit
Mitochondrial Permeability Transition Pore Assay
Synonyms
Mitochondrial Permeability Transition Pore; N/A; Mitochondrial Permeability Transition Pore Assay; MPTP; Mitochondrial Permeability Transition Pore assay kit
Samples
Cells
Usage Note
Do not mix or substitute reagents or materials from other kit lots or vendors.
Preparation and Storage
Stored at -20 degree C for 12 months, protected from light
Related Product Information for Mitochondrial Permeability Transition Pore assay kit
Principle of the Assay: Mitochondrial permeablity transition pore (MPTP), also known as magachannel, is a non selective high conductivity channel that exists between the inner and outer membranes of mitochondria and is composed of multiple protein complexes. MPTP may be involved in the release of mitochondrial components during cell death. The normal mitochondrial inner membrane of a cell can maintain a normal mitochondrial potential gradient to ensure cellular respiration and energy supply. With the intake and release of Ca2+, a low conductivity permeability transition pore switches back and forth between opening and closing. During apoptosis and pathological death of cells, the permeability of mitochondrial membrane potential transfer pore changes, Ca2+ overload, mitochondrial glutathione oxidation, increase of reactive oxygen species, including subsequent release of cytochrome C, and mitochondrial membrane potential decline all lead to the activation of MPTP. Mitochondrial Permeability Transition Pore Assay Kit s a more direct detection method for detecting the opening of MPTP than only based on mitochondrial membrane potential analysis. The principle is: Firstly, loading Calcein AM through passive transportation, which is a kind of cell staining reagent for fluorescent labeling of living cells. It can easily penetrate the living cell membrane and is cleaved by intracellular esterase to form the membrane-impermeable polar molecule Calcein, which is then trapped in the cell and causes the cytoplasm including mitochondria to emit strong green fluorescence. After adding CoCl2, the fluorescence from the cytoplasm is quenched by CoCl2, only left fluorescence in the mitochondria. As a control, cells can be loaded with Calcein AM and CoCl2, and treated with Ionomycin, so as to make cells load more Ca2+, which causes the activation of MPTP and quenching of mitochondrial fluorescence.
Product Categories/Family for Mitochondrial Permeability Transition Pore assay kit
Similar Products
Product Notes
The Mitochondrial Permeability Transition Pore (Catalog #AAA332620) is an Assay Kit and is intended for research purposes only. The product is available for immediate purchase. It is sometimes possible for the material contained within the vial of "Mitochondrial Permeability Transition Pore, Assay Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.Precautions
All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.Disclaimer
Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.Item has been added to Shopping Cart
If you are ready to order, navigate to Shopping Cart and get ready to checkout.