Reactivity
Mouse
Samples
Serum, plasma, Cell Culture Supernatants, body fluid and tissue homogenate
Assay Type
Competitive
Detection Range
2.5-50ng/mL
Sensitivity
0.1ng/mL
Preparation and Storage
Store all reagents at 2-8 degree C.
Related Product Information for DUB elisa kit
For Samples: Cell culture fluid, body fluid, tissue homogenate, serum and blood plasma
Intended Uses: This DUB ELISA kit is intended for laboratory research use only. The stop solution changes the color from blue to yellow and the intensity of the color is measured at 450 nm using a spectrophotometer. In order to measure the concentration of DUB in the sample, this DUB ELISA Kit includes a set of calibration standards. The calibration standards are assayed at the same time as the samples and allow the operator to produce a standard curve of Optical Density versus DUB concentration. The concentration of in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Principle of the Assay: The coated well immunoenzymatic assay for the quantitative measurement of DUB utilizes a multiclonal anti-DUB antibody and an DUB-HRP conjugate. The assay sample and buffer are incubated together with DUB-HRP conjugate in pre-coated plate for one hour. After the incubation period, the wells are decanted and washed five times. The wells are then incubated with a substrate for HRP enzyme. The product of the enzyme-substrate reaction forms a blue colored complex. Finally, a stop solution is added to stop the reaction, which will then turn the solution yellow. The intensity of color is measured spectrophotometrically at 450nm in a microplate reader. The intensity of the color is inversely proportional to the DUB concentration since DUB from samples and DUB-HRP conjugate compete for the anti-DUB antibody binding site. Since the number of sites is limited, as more sites are occupied by DUB from the sample, fewer sites are left to bind DUB-HRP conjugate. Standards of known DUB concentrations are run concurrently with the samples being assayed and a standard curve is plotted relating the intensity of the color (Optical Density) to the concentration of DUB. The DUB concentration in each sample is interpolated from this standard curve.
Intended Uses: This DUB ELISA kit is intended for laboratory research use only. The stop solution changes the color from blue to yellow and the intensity of the color is measured at 450 nm using a spectrophotometer. In order to measure the concentration of DUB in the sample, this DUB ELISA Kit includes a set of calibration standards. The calibration standards are assayed at the same time as the samples and allow the operator to produce a standard curve of Optical Density versus DUB concentration. The concentration of in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Principle of the Assay: The coated well immunoenzymatic assay for the quantitative measurement of DUB utilizes a multiclonal anti-DUB antibody and an DUB-HRP conjugate. The assay sample and buffer are incubated together with DUB-HRP conjugate in pre-coated plate for one hour. After the incubation period, the wells are decanted and washed five times. The wells are then incubated with a substrate for HRP enzyme. The product of the enzyme-substrate reaction forms a blue colored complex. Finally, a stop solution is added to stop the reaction, which will then turn the solution yellow. The intensity of color is measured spectrophotometrically at 450nm in a microplate reader. The intensity of the color is inversely proportional to the DUB concentration since DUB from samples and DUB-HRP conjugate compete for the anti-DUB antibody binding site. Since the number of sites is limited, as more sites are occupied by DUB from the sample, fewer sites are left to bind DUB-HRP conjugate. Standards of known DUB concentrations are run concurrently with the samples being assayed and a standard curve is plotted relating the intensity of the color (Optical Density) to the concentration of DUB. The DUB concentration in each sample is interpolated from this standard curve.
NCBI and Uniprot Product Information
NCBI GI #
NCBI GeneID
Molecular Weight
27,094 Da
NCBI Official Full Name
deubiquitinating enzyme
NCBI Official Synonym Full Names
ubiquitin specific peptidase 15
NCBI Official Symbol
USP15
NCBI Official Synonym Symbols
UNPH4; UNPH-2
NCBI Protein Information
ubiquitin carboxyl-terminal hydrolase 15; ubiquitin thioesterase 15; deubiquitinating enzyme 15; ubiquitin thiolesterase 15; ubiquitin-specific-processing protease 15
UniProt Protein Name
Ubiquitin carboxyl-terminal hydrolase 15
UniProt Gene Name
USP15
UniProt Synonym Gene Names
KIAA0529
UniProt Entry Name
UBP15_HUMAN
Similar Products
Product Notes
The Mouse DUB usp15 (Catalog #AAA82209) is an ELISA Kit and is intended for research purposes only. The product is available for immediate purchase. The AAA82209 ELISA Kit recognizes Mouse DUB. It is sometimes possible for the material contained within the vial of "Deubiquitinating enzyme, ELISA Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.Precautions
All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.Disclaimer
Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.Item has been added to Shopping Cart
If you are ready to order, navigate to Shopping Cart and get ready to checkout.