Loading...

Skip to main content
Call us at +1-800-604-9114 for more information about our products or contact us online Need help? +1-800-604-9114 or contact us
product-image-AAA126787_SC15.png Standard Curve (Sample) (Human CCL4 PicoKine ELISA Kit standard curve)

Human CCL4/MIP-1 beta ELISA Kit | CCL4 elisa kit

Human CCL4/MIP-1 beta PicoKine Quick ELISA Kit

Gene Names
CCL4; ACT2; G-26; HC21; LAG1; LAG-1; MIP1B; SCYA2; SCYA4; MIP1B1; AT744.1; MIP-1-beta
Reactivity
Human
Applications
ELISA
Synonyms
CCL4/MIP-1 beta; N/A; Human CCL4/MIP-1 beta PicoKine Quick ELISA Kit; CCL4 elisa kit
Ordering
Reactivity
Human
Specificity
Natural and recombinant Human CCL4
Assay Type
Sandwich
Samples
Cell culture supernatants, serum and plasma (heparin, EDTA, citrate)
Detection Range
15.6 pg/ml - 1,000 pg/ml
Sensitivity
<4 pg/ml
Applicable Applications for CCL4 elisa kit
ELISA
Intra-assay Precision
Intra-Assay Precision (Precision within an assay): Three samples of known concentration were tested on one plate to assess intra-assay precision.
Inter-assay Precision
Inter-Assay Precision (Precision across assays): Three samples of known concentration were tested in separate assays to assess inter-assay precision.
Preparation and Storage
Store at 4 degree C for 6 months, at -20 degree C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)

Standard Curve (Sample)

(Human CCL4 PicoKine ELISA Kit standard curve)

product-image-AAA126787_SC15.png Standard Curve (Sample) (Human CCL4 PicoKine ELISA Kit standard curve)
Related Product Information for CCL4 elisa kit
Background: Chemokine(C-C motif) ligand 4, also known as CCL4, is a protein which in humans is encoded by the CCL4 gene. It is a CC chemokine with specificity for CCR5 receptors. It is a chemoattractant for natural killer cells, monocytes and a variety of other immune cells. CCL4 is a major HIV-suppressive factor produced by CD8+ T cells. Performing-low memory CD8+ T cells that normally synthesize MIP-1-beta. the CCL4 gene was assigned to a slightly more distal location: 17q21-q23 rather than 17q11-q21.

Principle of the Assay: The Quick Picokine™ Human CCL4 Pre-Coated ELISA (Enzyme-Linked Immunosorbent Assay) kit is a solid phase immunoassay specially designed to measure Human CCL4 in cell culture supernatants, serum and plasma (heparin, EDTA, citrate). It uses our proprietary Quick ELISA technology. Quick ELISA technology employs capture antibodies conjugated to an affinity tag that is recognized by the polyclonal antibody used to coat our Quick ELISA plates. This approach to sandwich ELISA allows the formation of the antibody-analyte sandwich complex in a single step, significantly reducing assay time. The kit includes Human CCL4 protein as standards. To measure Human CCL4, add standards and samples to the wells, then add antibody cocktail. Wash the wells with PBS or TBS buffer, and add TMB. TMB is an HRP substrate and will be catalyzed to produce a blue color product, which changes into yellow after adding the acidic stop solution. The absorbance of the yellow product is linearly proportional to Human CCL4 in the sample. Read the absorbance of the yellow product in each well using a plate reader, and benchmark the sample wells' readings against the standard curve to determine the concentration of Human CCL4 in the sample.
Product Categories/Family for CCL4 elisa kit

NCBI and Uniprot Product Information

NCBI GI #
NCBI GeneID
UniProt Accession #
Molecular Weight
92
NCBI Official Full Name
C-C motif chemokine 4
NCBI Official Synonym Full Names
chemokine (C-C motif) ligand 4
NCBI Official Symbol
CCL4
NCBI Official Synonym Symbols
ACT2; G-26; HC21; LAG1; LAG-1; MIP1B; SCYA2; SCYA4; MIP1B1; AT744.1; MIP-1-beta
NCBI Protein Information
C-C motif chemokine 4; PAT 744; SIS-gamma; MIP-1-beta(1-69); secreted protein G-26; T-cell activation protein 2; G-26 T-lymphocyte-secreted protein; lymphocyte activation gene 1 protein; macrophage inflammatory protein 1-beta; small inducible cytokine A4
UniProt Protein Name
C-C motif chemokine 4
UniProt Gene Name
CCL4
UniProt Synonym Gene Names
LAG1; MIP1B; SCYA4; LAG-1; MIP-1-beta; ACT-2
UniProt Entry Name
CCL4_HUMAN

Similar Products

Product Notes

The Human CCL4 ccl4 (Catalog #AAA126787) is an ELISA Kit and is intended for research purposes only. The product is available for immediate purchase. The AAA126787 ELISA Kit recognizes Human CCL4. AAA Biotech's CCL4/MIP-1 beta can be used in a range of immunoassay formats including, but not limited to, ELISA. Researchers should empirically determine the suitability of the CCL4 ccl4 for an application not listed in the data sheet. Researchers commonly develop new applications and it is an integral, important part of the investigative research process. It is sometimes possible for the material contained within the vial of "CCL4/MIP-1 beta, ELISA Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Submit a Question

Please complete the form below and a representative will contact you as soon as possible.

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.