Loading...

Skip to main content
Call us at +1-800-604-9114 for more information about our products or contact us online Need help? +1-800-604-9114 or contact us

Coagulation factor XII ELISA Kit | F12 elisa kit

Coagulation factor XII, Human, ELISA kit

Gene Names
F12; HAF; HAE3; HAEX
Reactivity
Human
Does not react: Mouse - No, Pig, Rat
Synonyms
Coagulation factor XII; N/A; Coagulation factor XII, Human, ELISA kit; Hageman factor; Coagulation Factor XII Human ELISA kit 1 x 96 det.; F12 elisa kit
Ordering
Reactivity
Human
Does not react: Mouse - No, Pig, Rat
Sequence Length
237
Samples
Plasma and serum
Preparation and Storage
Product should be stored at 4 degree C.
Under recommended storage conditions, product is stable for at least six months.
Related Product Information for F12 elisa kit
Intended Uses: The human coagulation factor XII ELISA kit is to be used for the in vitro quantitative determination of coagulation factor XII in plasma and serum. This kit is intended for laboratory research use only. The analysis should be performed by trained laboratory professionals.

Background/Introduction: FXII is a serine protease and plays a role in blood coagulation, fibrinolysis, kinin and complement systems. The protein is the zymogen of the serine protease factor XIIa (FXIIa). FXII is converted to FXIIa through autoactivation induced by contact to charged surfaces, also known as the plasma contact system. FXII is predominantly synthesized in the liver and is composed of fibronectin type I and II domains, two epidermal growth factor-like domains, a kringle region, a proline-rich domain and a catalytic domain. Its molecular weight is approximately 80kDa on SDS-PAGE gel electroforeses. The protein circulates in the plasma at a concentration of 30-35 ug/ml. FXII forms the plasma contact system together with high molecular weight kininogen and plasma kallikrein. FXII autoactivates when these three proteins form a complex on negatively charged nonphysiological surfaces, like inorganic surfaces (eg silicon tubes) or macromolecular organic surfaces (eg heparin) bound to the surface of different cell types, including endothelial cells, platelets and neutrophils. It can trigger blood coagulation and generation of proinflammatory bradykinin. After surface complexation, FXII autoactivates into FXIIa, also called factor XII fragment(XIIf). Once small amounts of kallikrein are formed a positive feedback loop is active leading to enhanced conversion into FXIIa. The activation leads to a series of active enzyme formation. FXIIa converts prekallikrein to kallikrein and kallikrein digests kinogen to liberate proinflammatory bradykinin. Bradykinin triggers inflammatory reactions via activating endothelial cells resulting in vasodilatation, increased vascular permeability and production of other mediators like nitric oxide. The contact system has the ability to activate the complement system via the classical pathway. Simultaneous activation of both systems may lead to pathological conditions, like hereditary angioedema in individuals with dysfunctional C1-inhibitor (C1-IHB). FXIIa can activate complement protein C1r and to a lesser degree C1s in absence of C1-IHB. This leads to unimpeded bradykinin formation resulting in angioedema. Other interactions with complement system are found on the level of gC1qR and MASP-1.
Product Categories/Family for F12 elisa kit
References
1. Madsen DE et al; ELISA for determination of total coagulation factor XII concentration inHuman plasma. J Immunol Methods, 2013, 394: 32-9

NCBI and Uniprot Product Information

NCBI GI #
NCBI GeneID
NCBI Official Full Name
coagulation factor XII, partial
NCBI Official Synonym Full Names
coagulation factor XII
NCBI Official Symbol
F12
NCBI Official Synonym Symbols
HAF; HAE3; HAEX
NCBI Protein Information
coagulation factor XII

Similar Products

Product Notes

The Human Does not react: Mouse - No, Pig, Rat F12 (Catalog #AAA77812) is an ELISA Kit and is intended for research purposes only. The product is available for immediate purchase. The AAA77812 ELISA Kit recognizes Human Does not react: Mouse - No, Pig, Rat F12. It is sometimes possible for the material contained within the vial of "Coagulation factor XII, ELISA Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Submit a Question

Please complete the form below and a representative will contact you as soon as possible.