Loading...

Skip to main content
Call us at +1-800-604-9114 for more information about our products or contact us online Need help? +1-800-604-9114 or contact us
product-image-AAA254112_SC15.png Standard Curve (Sample) (Typical Standard Curve for the Creatinine Serum Detection Kit StressXpress - AAA254112. Assay Type: Direct Enzyme. Detection Method: Colorimetric Assay. Assay Range: 0.5 - 4 mg/dl.)

Creatinine Serum Detection Kit

Creatinine Serum Detection Kit

Reactivity
Human, Mouse, Rabbit, Rat, Sheep
Synonyms
Creatinine Serum; N/A; Creatinine Serum Detection Kit; N-Carbamimidoyl-N-methylglycine Detection Kit; Methylguanidoacetic acid Detection Kit; Creatinine Serum detection kit
Ordering
Reactivity
Human, Mouse, Rabbit, Rat, Sheep
Assay Type
Direct Quantitative Assay
Detection Method
Colorimetric Assay
Sample
Serum, Plasma
Detection Range
0.5-4mg/dl
Sensitivity
0.085mg/dl
Utility
Colorimetric assay used to measure creatinine in samples.
Precision
Intra-Assay Precision: Four human serum samples were run in triplicate on a same-day assay determined that the mean and precision of the calculated concentrations were: Sample 1- 0.75 mg/dL, 5% CV, Sample 2- 0.78 mg/dL, 6% CV, Sample 3- 0.6 mg/dL, 4% CV, Sample 4- 0.76 mg/dL, 6% CV
Inter-Assay Precision: Four human serum samples were run in triplicate on a same-day assay determined that the total range of 4-6% represents the variation between different assays.
Platform
Microplate
Number of Samples
91 samples in duplicate
Assay Overview
The Creatinine Serum Detection Kit is designed to quantitatively measure creatinine present in serum samples. A creatinine standard, calibrated to a creatinine standard, is provided to generate a standard curve for the assay and all samples should be read off the standard curve. Standards or samples are pipetted into a clear microtiter plate. An assay diluent is added to all standards, controls and samples. The color generating reaction is initiated with the StressXpress Creatinine Reagent, which is pipetted into each well.The assay utilizes a kinetic absorbance method to overcome interference by colored compounds in serum. The absorbance of the colored product is read in a microtiter plate reader capable of measuring 490nm wavelength. For a total of 30 minutes, the optical density is read at 1 minute intervals. The concentration of creatinine is calculated using the Kinetic Mode software and samples are compared to the curve generated from the standards, or by using the Excel worksheet available for free download at our web site. The Jaffe reaction used in this kit has been modified to read creatinine levels in serum (8).
Preparation and Storage
Store at 4 degree C

Standard Curve (Sample)

(Typical Standard Curve for the Creatinine Serum Detection Kit StressXpress - AAA254112. Assay Type: Direct Enzyme. Detection Method: Colorimetric Assay. Assay Range: 0.5 - 4 mg/dl.)

product-image-AAA254112_SC15.png Standard Curve (Sample) (Typical Standard Curve for the Creatinine Serum Detection Kit StressXpress - AAA254112. Assay Type: Direct Enzyme. Detection Method: Colorimetric Assay. Assay Range: 0.5 - 4 mg/dl.)
Related Product Information for Creatinine Serum detection kit
Colorimetric measurement of creatinine
Creatinine (2-amino-1-methyl-5H-imadazol-4-one) is a metabolite of phosphocreatine (p-creatine), a molecule used as a store for high-energy phosphate that can be utilized by tissues for the production of ATP (1). Creatine either comes from the diet or synthesized from the amino acids arginine, glycine, and methionine. This occurs in the kidneys and liver, although other organ systems may be involved and species-specific differences may exist (2). Creatine and p-creatine are converted non-enzymatically to the metabolite creatinine, which diffuses into the blood and is excreted by the kidneys. In vivo , this conversion appears to be irreversible and in vitro it is favored by higher temperatures and lower pH2. Creatinine forms spontaneously from p-creatine (3). Under normal conditions, its formation occurs at a rate that is relatively constant and as intra-individual variation is <15% from day to day, creatinine is a useful tool for normalizing the levels of other molecules found in urine. Additionally altered creatinine levels may be associated with other conditions that result in decreased renal blood flow such as diabetes and cardiovascular disease (4-6).
Product Categories/Family for Creatinine Serum detection kit
References
1. Wallimann, T. et al., Biochem. J., 2000, 281, 21-40.2. Wyss, M. and Kaddurah-Daouk, R., Physiol. Rev., 2000, 80, 1107-1213.3. Raja Iyengar, M. et al., J. Biol. Chem, 1985, 260, 7562-7567.4. Manjunath, G. et al., Postgrad. Med. 2001, 110, 55-62.5. Gross, J.L. et al., Diabetes Care, 2005, 28, 164-176.6. Anavekar, N.S. et al., New Engl. J. Med., 2004, 351, 1285-1295.

Similar Products

Product Notes

The Human, Mouse, Rabbit, Rat, Sheep Creatinine Serum (Catalog #AAA254112) is a Detection Kit and is intended for research purposes only. The product is available for immediate purchase. The AAA254112 Detection Kit recognizes Human, Mouse, Rabbit, Rat, Sheep Creatinine Serum. It is sometimes possible for the material contained within the vial of "Creatinine Serum, Detection Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Submit a Question

Please complete the form below and a representative will contact you as soon as possible.

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.