Loading...

Skip to main content
Call us at +1-800-604-9114 for more information about our products or contact us online Need help? +1-800-604-9114 or contact us
product-image-AAA77853_SC15.png Standard Curve (Sample)

Interleukin-10 ELISA Kit | IL-10 elisa kit

Interleukin-10 (IL-10)

Gene Names
IL10; CSIF; TGIF; GVHDS; IL-10; IL10A
Synonyms
Interleukin-10; N/A; Interleukin-10 (IL-10); IL-10 elisa kit
Ordering
Specificity
This sandwich ELISA can detect both natural and recombinant human IL-10. This kit exhibits no significant cross-reactivity with human IL-1?, IL-2, IL-3, IL-4, IL-6, IL-7, IL-8, TNF-?, TNF-?, IFN-?. There is 2% reaction with recombinant mouse IL-10.
Sequence Length
178
Samples
Cell Culture Supernatant, serum, plasma, and other biological fluids
Assay Type
Sandwich
Sensitivity
The minimum detectable quantities of human IL-10 as observed by the standard curve generated for both Calibrator Diluent I and Calibrator Diluent II are 3.5 pg/mL and 3.7pg/mL respectively. The two standard deviations above the mean optical density of the 20 replicates of the zero standard were defined as the minimum detectable quantities.
Intra-assay Precision
To determine within-run precision, three different samples of known concentration were assayed by replicates of twenty in 1 assay.
Inter-assay Precision
To determine between-run precision, three different samples of known concentration were assayed by replicates on 25 different assays.
Intended Uses
This Human Interleukin 10 ELISA Kit is to be used for the in vitro quantitative determination of human interleukin 10 (IL-10) concentrations in cell culture supernatant, serum, plasma, and other biological fluids. This kit is intended FOR LABORATORY RESEARCH USE ONLY and is not to be used in therapeutic procedures.

Standard Curve (Sample)

product-image-AAA77853_SC15.png Standard Curve (Sample)
Related Product Information for IL-10 elisa kit
Principle of the assay: This IL-10 enzyme linked immunosorbent assay (ELISA) applies a technique called a quantitative sandwich immunoassay. The microtiter plate provided in this kit has been pre-coated with a monoclonal antibody specific to IL-10. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated monoclonal antibody preparation specific for IL-10 and incubated. IL-10, if present, will bind and become immobilized by the antibody pre-coated on the wells and then will become "sandwiched" by biotin conjugate. The microtiter plate wells are thoroughly washed to remove unbound IL-10 and other components of the sample. In order to quantitatively determine the amount of IL-10 present in the sample, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Avidin is a tetramer containing four identical subunits, each having a high affinity-binding site for biotin. The wells are thoroughly washed to remove all unbound HRP-conjugated Avidin and a TMB (3,3'5, 5' tetramethyl-benzidine) substrate solution is added to each well. The enzyme (HRP) and substrate are allowed to react over a short incubation period. Only those wells that contain IL-10, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm +/- 2 nm. In order to measure the concentration of IL-10 within the samples, this kit includes two calibration diluents (Calibrator Diluent I for serum/plasma testing and Calibrator Diluent II for cell culture supernatant testing.) According to the testing system, the standard provided is diluted (2-fold) with the appropriate Calibrator Diluent and assayed at the same time as the samples. This allows the operator to produce a standard curve of Optical Density (O.D) versus IL-10 concentration (pg/mL). The concentration of IL-10 in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Product Categories/Family for IL-10 elisa kit

NCBI and Uniprot Product Information

NCBI GI #
NCBI GeneID
NCBI Accession #
NCBI GenBank Nucleotide #
Molecular Weight
20,517 Da
NCBI Official Full Name
interleukin-10
NCBI Official Synonym Full Names
interleukin 10
NCBI Official Symbol
IL10
NCBI Official Synonym Symbols
CSIF; TGIF; GVHDS; IL-10; IL10A
NCBI Protein Information
interleukin-10; T-cell growth inhibitory factor; cytokine synthesis inhibitory factor
UniProt Protein Name
Interleukin-10
UniProt Gene Name
IL10
UniProt Entry Name
IL10_HUMAN

Similar Products

Product Notes

The IL-10 il10 (Catalog #AAA77853) is an ELISA Kit and is intended for research purposes only. The product is available for immediate purchase. It is sometimes possible for the material contained within the vial of "Interleukin-10, ELISA Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Submit a Question

Please complete the form below and a representative will contact you as soon as possible.

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.