Loading...

Skip to main content
Call us at +1-800-604-9114 for more information about our products or contact us online Need help? +1-800-604-9114 or contact us
product-image-AAA147653_SC15.jpg Standard Curve (Sample)

Mouse Nitric Oxide Synthase 2, Inducible (NOS2) DIY ELISA Kit | NOS2 diy elisa kit

Mouse Nitric Oxide Synthase 2, Inducible (NOS2) ELISA Kit DIY Materials

Gene Names
NOS2; NOS; INOS; NOS2A; HEP-NOS
Reactivity
Mouse
Synonyms
Nitric Oxide Synthase 2, Inducible (NOS2); N/A; Mouse Nitric Oxide Synthase 2, Inducible (NOS2) ELISA Kit DIY Materials; NOS2A; INOS; HEP-NOS; I-NOS; Hepatocytes Oxide Synthase; Peptidyl-cysteine S-nitrosylase NOS2; NOS2 diy elisa kit
Ordering
Reactivity
Mouse
Specificity
The Abs in the kit have high sensitivity and excellent specificity for detection of Nitric Oxide Synthase 2, Inducible (NOS2). No significant cross-reactivity or interference between Nitric Oxide Synthase 2, Inducible (NOS2) and analogues was observed.
Sequence Length
1153
Assay Type
Double-antibody Sandwich ELISA for Antigen Detection
Samples
Tissue homogenates, cell lysates, cell culture supernates and other biological fluids.
Detection Range
0.312-20ng/mL
Sensitivity
0.116ng/mL
Reagent Contents
Capture Antibody, Detection Antibody, Standard, Streptavidin-HRP, TMB Substrate, 96-well Plate
Product Usage
1. Coat the plates with 100muL per well of working solution of Capture Antibody.incubate overnight at 4 degree C or incubate at 37 degree C for 2 hours.
2. Aspirate and wash 1 time.
3. Block the plates with 200 muL per well of working solution of Blocking Buffer. Incubate at 37 degree C for 1.5 hours.
4. Aspirate and wash 1 time. The plates are now ready for sample detection, the protocol is the same as regular ELISA.
Other Reagents Required
ELISA/CLIA Support Pack 1. ( )
Preparation and Storage
Antibodies, Standard and Streptavidin-HRP should be stored at -20 degree C. TMB should be stored at 4 degree C. 96-well Plate could be stored at room temperature. The contents are valid for twelve months. They are stable for one month after opening when stored at 4 degree C.

Standard Curve (Sample)

product-image-AAA147653_SC15.jpg Standard Curve (Sample)
Product Categories/Family for NOS2 diy elisa kit

NCBI and Uniprot Product Information

NCBI GI #
NCBI GeneID
NCBI Accession #
NCBI GenBank Nucleotide #
UniProt Accession #
Molecular Weight
126,749 Da
NCBI Official Full Name
nitric oxide synthase, inducible
NCBI Official Synonym Full Names
nitric oxide synthase 2
NCBI Official Symbol
NOS2
NCBI Official Synonym Symbols
NOS; INOS; NOS2A; HEP-NOS
NCBI Protein Information
nitric oxide synthase, inducible
UniProt Protein Name
Nitric oxide synthase, inducible
UniProt Gene Name
NOS2
UniProt Synonym Gene Names
NOS2A; HEP-NOS; Inducible NOS; iNOS

Similar Products

Product Notes

The Mouse NOS2 nos2 (Catalog #AAA147653) is a DIY ELISA Kit and is intended for research purposes only. The product is available for immediate purchase. The AAA147653 DIY ELISA Kit recognizes Mouse NOS2. It is sometimes possible for the material contained within the vial of "Nitric Oxide Synthase 2, Inducible (NOS2), DIY ELISA Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Submit a Question

Please complete the form below and a representative will contact you as soon as possible.

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.