Application Data
(Figure 1. U2OS cells before and after drug treatment, imaging after incubation with Fluo-4 fluorescent probe (fluorescence microscope FITC filter))
Application Data
(The Fluo-series shows enhanced fluorescence upon binding to Ca2+, unlike the UV-excited probes fura-2 and indo-1, and does not undergo spectral drift. The fluorescence optical density was enhanced at least 100-fold after binding to Ca 2 +. The spectral properties of Fluo-2, Fluo-3, and Fluo-4 are shown in following Table.)
Calcium ion Ca2+ indicated fluorescent probe Fluo series with Ca2+ in combination with the fluorescence enhancement, it is mainly used to detect all aspects of calcium ion signaling pathway, namely calcium flow, such as pharmacological screening at the cellular level, second messenger, neurotransmitter, photoactivation of chelator, etc.
Fluo-2 was one of the first Fluo series of calcium ion indicators invented by Dr. Roger Tsien. Fluo-2 is brighter in cells than Fluo-3 and Fluo-4, mainly probably due to the higher capacity of most cells to load Fluo-2 than Fluo-3 and Fluo-4. Therefore, Fluo-2 is often used for intracellular calcium ion imaging. Fluo-3 is often used on flow cytometry analysis because it can be excited by an argon ion laser 488nmand after binding with Ca2+, a very bright fluorescent signal is emitted.
Fluo-4 is an analogue of Fluo-3 replacing chlorine atoms with two fluorine atoms. This small structural change enhances the fluorescence signal of Fluo-4 probe at 488nm excitation light. The signal is stable and can be applied to confocal microscopy, flow cytometer, fluorescence luminometer / plate reader.
Similar Products
Product Notes
The ca2+ fluorescent (fluo-3) (Catalog #AAA269816) is a Probe and is intended for research purposes only. The product is available for immediate purchase. It is sometimes possible for the material contained within the vial of "ca2+ fluorescent (fluo-3), Probe" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.Precautions
All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.Disclaimer
Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.Item has been added to Shopping Cart
If you are ready to order, navigate to Shopping Cart and get ready to checkout.