Loading...

Skip to main content
Call us at +1-800-604-9114 for more information about our products or contact us online Need help? +1-800-604-9114 or contact us
product-image-AAA62237_AD11.jpg Application Data (Antibody (Ab) Neutralization Assays with SARS-CoV-2-614G PP.)

MERS pseudovirus

MERS Pseudoviral Particles

Synonyms
MERS; N/A; MERS Pseudoviral Particles; MERS pseudovirus
Ordering
Form/Format
10 ml (2 tubes, 5 mL/tube), for 2 multi-well plates
Features
Robust: Excellent signal to noise (basal) ratio
Easy to use: Amenable to HTS format (96-well, 384-well and 1536-well format)
Dry Ice Shipment
Extra charge fee may add to your shipping cost as dry ice is required to ship this product.
Preparation and Storage
Ships on dry ice. Upon receiving this item, store at -70°C right away. Thaw* each vial immediately before use *Note: Read the instruction for thawing in the assay protocol below carefully. Do not aliquot and refreeze. Stable for six months from the date of receipt when stored at -70°C.

Dry Ice Shipment: Extra charge fee may add to your shipping cost as dry ice is required to ship this product.

Shipping Note: Product is available for shipment in the United States, Canada and European countries. Please inquire for shipment to other countries.

Application Data

(Antibody (Ab) Neutralization Assays with SARS-CoV-2-614G PP.)

product-image-AAA62237_AD11.jpg Application Data (Antibody (Ab) Neutralization Assays with SARS-CoV-2-614G PP.)

Application Data

(Figure 2. Pseudoviral Particle (PP) Infection Assays MERS pseudoviral particles with Vero-E6 cells, or HUH-7 cells, or CALU-3 cells in 96-well format.Legends: MERS-PP: MLV w/ MERS spike protein (AAA62237)DelENV: MLV control (w/o envelope spike protein))

product-image-AAA62237_AD13.jpg Application Data (Figure 2. Pseudoviral Particle (PP) Infection Assays MERS pseudoviral particles with Vero-E6 cells, or HUH-7 cells, or CALU-3 cells in 96-well format.Legends: MERS-PP: MLV w/ MERS spike protein (AAA62237)DelENV: MLV control (w/o envelope spike protein))

Application Data

(Illustration of the replication-deficient MLV particle pseudotyped with MERS Spike protein)

product-image-AAA62237_AD15.jpg Application Data (Illustration of the replication-deficient MLV particle pseudotyped with MERS Spike protein)
Related Product Information for MERS pseudovirus
Our MERS Pseudoviral Particles are replication-deficient MLV pseudotyped with the MERS spike protein (Genbank Accession # AHY21469.1). They also contain the ORF for firefly luciferase as a reporter. They establish a pseudovirus entry assay for MERS as the spike protein mediated cell entry can be conveniently measured via the luciferase reporter activity. This pseudovirus assay isolates the MERS viral entry from other steps of the viral infection cycle.

Similar Products

Product Notes

The MERS (Catalog #AAA62237) is a Pseudovirus and is intended for research purposes only. The product is available for immediate purchase. It is sometimes possible for the material contained within the vial of "MERS, Pseudovirus" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Submit a Question

Please complete the form below and a representative will contact you as soon as possible.

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.