Reactivity
Rat
Specificity
This assay has high sensitivity and excellent specificity for detection of COL1. No significant cross-reactivity or interference between COL1 and analogues was observed.
Sequence Length
1,366
Assay Type
Quantitative Sandwich
Samples
Rat serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Detection Range
0.625-40ng/mL
Sensitivity
< 0.219ng/mL
Intra-assay Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level COL1 were tested 20 times on one plate, respectively. Intra-Assay: CV<10%
Inter-assay Precision
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level COL1 were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100. Inter-Assay: CV<12%
Preparation and Storage
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Related Product Information for COL1 elisa kit
Principle of the Assay: The microplate provided in this kit has been pre-coated with an antibody specific to COL1. Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to COL1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain COL1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of COL1 in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Intended Uses: The kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of COL1 in rat serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids.
Intended Uses: The kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of COL1 in rat serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids.
Product Categories/Family for COL1 elisa kit
References
Temporal changes in the muscle extracellular matrix due to volumetric muscle loss injury; Connect Tissue Res; 2022 Mar;63(2):124-137.; PMID: 33535825; Daniel B Hoffman; School of Kinesiology, University of Minnesota, Minneapolis, MN, USA.
NCBI and Uniprot Product Information
NCBI GI #
NCBI GeneID
Molecular Weight
129,314 Da
NCBI Official Full Name
Collagen, type I, alpha 2
NCBI Official Synonym Full Names
collagen, type I, alpha 2
NCBI Official Symbol
COL1A2
NCBI Official Synonym Symbols
OI4
NCBI Protein Information
collagen alpha-2(I) chain
UniProt Protein Name
Collagen alpha-2(I) chain
UniProt Gene Name
COL1A2
UniProt Entry Name
CO1A2_HUMAN
Similar Products
Product Notes
The Rat COL1 col1a2 (Catalog #AAA20716) is an ELISA Kit and is intended for research purposes only. The product is available for immediate purchase. The AAA20716 ELISA Kit recognizes Rat COL1. It is sometimes possible for the material contained within the vial of "Collagen Type I (COL1), ELISA Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.Precautions
All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.Disclaimer
Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.Item has been added to Shopping Cart
If you are ready to order, navigate to Shopping Cart and get ready to checkout.