Skip to main content
Call us at +1-800-604-9114 for more information about our products or contact us online
product-image-AAA11577_SC.jpg Standard Curve (Sample)

Human P-Selectin ELISA Kit | SELP elisa kit

Human P-Selectin PicoKine ELISA Kit

Gene Names
SELP; CD62; GRMP; PSEL; CD62P; GMP140; LECAM3; PADGEM
Reactivity
Human
Synonyms
P-Selectin; N/A; Human P-Selectin PicoKine ELISA Kit; P-selectin; selectin P (granule membrane protein 140kDa, antigen CD62); Antigen CD62; CD62; CD62 antigen like family member P; CD62 antigen-like family member P; CD62P; FLJ45155; GMP 140; GMP-140; GMP140; Granule membrane protein 140; Granule membrane protein 140kDa; Granulocyte membrane protein; GRMP; LECAM3; Leukocyte endothelial cell adhesion molecule 3; Leukocyte-endothelial cell adhesion molecule 3; LYAM3_HUMAN; P selectin; PADGEM; Platelet activation dependent granule external membrane protein; Platelet activation dependent granule-external membrane protein; Platelet alpha granule membrane protein; PSEL; Selectin P; Selectin P (granule membrane protein 140kDa antigen CD62); SELP; SELP elisa kit
Ordering
For Research Use Only!
Reactivity
Human
Specificity
Natural and recombinant Human SELP
Sequence Length
830
Samples
Cell culture supernatants, serum and plasma (heparin, edta, citrate)
Detection Range
156 pg/ml - 10,000 pg/ml
Sensitivity
<5 pg/ml
Intra-assay Precision
Intra-Assay Precision (Precision within an assay): Three samples of known concentration were tested on one plate to assess intra-assay precision.
Inter-assay Precision
Inter-Assay Precision (Precision across assays): Three samples of known concentration were tested in separate assays to assess inter-assay precision.
Preparation and Storage
Store at 4 degree C for 6 months, at -20 degree C for 12 months. Avoid multiple freeze-thaw cycles (Shipped with wet ice.)

Standard Curve (Sample)

product-image-AAA11577_SC.jpg Standard Curve (Sample)
Related Product Information for SELP elisa kit
Principle of the Assay: The Picokine™ Human SELP Pre-Coated ELISA (Enzyme-Linked Immunosorbent Assay) kit is a solid-phase immunoassay specially designed to measure Human SELP with a 96-well strip plate that is pre-coated with antibody specific for SELP. The detection antibody is a biotinylated antibody specific for SELP. The capture antibody is monoclonal antibody from mouse and the detection antibody is polyclonal antibody from goat. The kit contains recombinant Human SELP with immunogen: Expression system for standard: NS0; Immunogen sequence: W42-A771. The kit is analytically validated with ready-to-use reagents. To measure Human SELP, add standards and samples to the wells, then add the biotinylated detection antibody. Wash the wells with PBS or TBS buffer, and add Avidin-Biotin-Peroxidase Complex (ABC-HRP). Wash away the unbounded ABC-HRP with PBS or TBS buffer and add TMB. TMB is an HRP substrate and will be catalyzed to produce a blue color product, which changes into yellow after adding the acidic stop solution. The absorbance of the yellow product at 450nm is linearly proportional to Human SELP in the sample. Read the absorbance of the yellow product in each well using a plate reader, and benchmark the sample wells' readings against the standard curve to determine the concentration of Human SELP in the sample.

Background/Introduction: P-selectin, also called GMP-140, CD62, or selectin P, is a 140-kD adhesion molecule, expressed at the surface of activated cells, that mediates the interaction of activated endothelial cells or platelets with leukocytes. It is stored in secretory granules and expressed at the plasma membrane after cell activation. It is known to play an important role in atherosclerosis. The major ligand for P-selectin on leukocytes is P-selectin glycoprotein ligand-1 (PSGL-1). The standard product used in this kit is recombinant human P-Selectin, excluding intercellular P-Selectin and transmembrane domain. It has 730 amino acids sequence with the molecular mass of 80 KDa.

NCBI and Uniprot Product Information

NCBI GI #
NCBI GeneID
UniProt Accession #
Molecular Weight
90,834 Da
NCBI Official Full Name
P-selectin
NCBI Official Synonym Full Names
selectin P (granule membrane protein 140kDa, antigen CD62)
NCBI Official Symbol
SELP
NCBI Official Synonym Symbols
CD62; GRMP; PSEL; CD62P; GMP140; LECAM3; PADGEM
NCBI Protein Information
P-selectin; GMP-140; granule membrane protein 140; granulocyte membrane protein; CD62 antigen-like family member P; platelet alpha-granule membrane protein; leukocyte-endothelial cell adhesion molecule 3; platelet activation dependent granule-external membrane protein
UniProt Protein Name
P-selectin
UniProt Gene Name
SELP
UniProt Synonym Gene Names
GMRP; GRMP; GMP-140; LECAM3; PADGEM
UniProt Entry Name
LYAM3_HUMAN

Similar Products

Product Notes

The Human SELP selp (Catalog #AAA11577) is an ELISA Kit and is intended for research purposes only. The product is available for immediate purchase. The AAA11577 ELISA Kit recognizes Human SELP. It is sometimes possible for the material contained within the vial of "P-Selectin, ELISA Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Submit a Question

Please complete the form below and a representative will contact you as soon as possible.

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.