Human matrix metallopeptidase 14 (membrane-inserted) ELISA Kit | MMP14 elisa kit
Human Matrix Metalloproteinase 14, MMP-14 ELISA Kit
Gene Names
MMP14; MMP-14; MMP-X1; MT-MMP; MT1MMP; MTMMP1; WNCHRS; MT1-MMP; MT-MMP 1
Reactivity
Human
Synonyms
matrix metallopeptidase 14 (membrane-inserted); N/A; Human Matrix Metalloproteinase 14, MMP-14 ELISA Kit; Human Matrix Metalloproteinase 14; MMP-14 ELISA Kit; MMP-X1; MT1-MMP; MTMMP1; matrix metalloproteinase 14; matrix metalloproteinase 14 (membrane-inserted) ; membrane type 1 metalloprotease; membrane-type matrix metalloproteinase 1; membrane-type-1 matrix m; MMP14 elisa kit
Reactivity
Human
Specificity
This assay has high sensitivity and excellent specificity for detection of human MMP-14. No significant cross-reactivity or interference between human MMP-14 and analogues was observed.
Sequence Length
582
Samples
Serum, plasma and tissue homogenates
Assay Type
Sandwich
Detection Range
3.12 ng/ml-200 ng/ml.
Sensitivity
The minimum detectable dose of human MMP-14 is typically less than 0.78 ng/ml. The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. It was determined the mean O.D value of 20 replicates of the zero standard added by their three standard deviations.
Intra-assay Precision
Intra-assay Precision (Precision within an assay): CV%<8%. Three samples of known concentration were tested twenty times on one plate to assess.
Inter-assay Precision
Inter-assay Precision (Precision between assays): CV%<10%. Three samples of known concentration were tested in twenty assays to assess.
Preparation and Storage
Unopened test kits should be stored at 2 to 8 degree C upon receipt. Please refer to pdf manual for further storage instructions.
Related Product Information for MMP14 elisa kit
Principle of the assay: This assay employs the quantitative sandwich enzyme immunoassay technique. Antibody specific for MMP-14 has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and any MMP-14 present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conjugated antibody specific for MMP-14 is added to the wells. After washing, avidin conjugated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound avidin-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of MMP-14 bound in the initial step. The color development is stopped and the intensity of the color is measured.
NCBI and Uniprot Product Information
NCBI GI #
NCBI GeneID
NCBI Accession #
NCBI GenBank Nucleotide #
Molecular Weight
65,894 Da
NCBI Official Full Name
matrix metalloproteinase-14 preproprotein
NCBI Official Synonym Full Names
matrix metallopeptidase 14 (membrane-inserted)
NCBI Official Symbol
MMP14
NCBI Official Synonym Symbols
MMP-14; MMP-X1; MT-MMP; MT1MMP; MTMMP1; WNCHRS; MT1-MMP; MT-MMP 1
NCBI Protein Information
matrix metalloproteinase-14; membrane type 1 metalloprotease; membrane-type-1 matrix metalloproteinase
UniProt Protein Name
Matrix metalloproteinase-14
UniProt Gene Name
MMP14
UniProt Synonym Gene Names
MMP-14; MT-MMP 1; MTMMP1; MT1-MMP; MT1MMP
UniProt Entry Name
MMP14_HUMAN
Similar Products
Product Notes
The Human MMP14 mmp14 (Catalog #AAA80664) is an ELISA Kit and is intended for research purposes only. The product is available for immediate purchase. The AAA80664 ELISA Kit recognizes Human MMP14. It is sometimes possible for the material contained within the vial of "matrix metallopeptidase 14 (membrane-inserted), ELISA Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.Precautions
All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.Disclaimer
Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.Item has been added to Shopping Cart
If you are ready to order, navigate to Shopping Cart and get ready to checkout.