Loading...

Skip to main content
Call us at +1-800-604-9114 for more information about our products or contact us online Need help? +1-800-604-9114 or contact us
product-image-AAA78592_AD11.jpg Application Data (Figure-3: Separation of human target population cells (red-filled) from basophils (black-dashed) in flow cytometry analysis (surface staining) of human peripheral whole blood stained using Lineage Cocktail FITC (20 ul cocktail/100 ul of peripheral whole blood).)

Human Lineage Cocktail (CD3/CD14/CD16/CD19/CD20/CD56) Assay Kit | CD3/CD14/CD16/CD19/CD20/CD56 assay kit

Lineage Cocktail Assay kit (CD3/CD14/CD16/CD19/CD20/CD56) FITC Conjugated

Reactivity
Human
Applications
Flow Cytometry, Functional Assay
Synonyms
Lineage Cocktail (CD3/CD14/CD16/CD19/CD20/CD56), Assay Kit; Lineage Cocktail Assay kit (CD3/CD14/CD16/CD19/CD20/CD56) FITC Conjugated; CD3/CD14/CD16/CD19/CD20/CD56 assay kit
Ordering
Reactivity
Human
Clonality
Monoclonal
Clone Number
MEM 57, MEM-15, LNK16, LT19, LT20 and MEM-188
Specificity
The monoclonal antibody MEM-57 reacts with CD3 complex, expressed on all peripheral blood T lymphocytes. The antibody MEM-15 reacts with CD14, expressed on monocytes, macrophages and weakly on neutrophils. The antibody LNK16 reacts with CD16, expressed on NK-cells, monocytes, macrophages and neutrophils. The antibody LT19 reacts with CD19, expressed on B lymphocytes. The antibody LT20 reacts with CD20, expressed on B lymphocytes. The antibody MEM-188 reacts with CD56, expressed on NK lymphocytes.
Form/Format
Purified. (PBS) containing 15mM sodium azide and 0.2% (w/v) high-grade protease free Bovine Serum Albumin (BSA) as a stabilizing agent.
Use
The Lineage Cocktail (CD3/CD14/CD16/CD19/CD20/CD56) FITC consists of the mixture of antibodies which stain human lymphocytes, monocytes, eosinophils and neutrophils. Peripheral blood dendritic cells and basophils can be identified  by lack of staining with this reagent.
Principle
This test is based on specific binding of monoclonal antibodies to the antigenic determinants expressed on the surface of human lymphocytes, monocytes, eosinophils and neutrophils in peripheral blood. Dendritic cells and basophils can be identified in the peripheral blood by their lack of staining with this Lineage Cocktail using common flow cytometer device equipped with 488 nm laser. The monoclonal antibodies used in the Lineage Cocktail are labeled with Fluorescein isothiocyanate (FITC) which is excited by single laser beam from a flow cytometer during analysis. Staining of human blood cells is performed by incubation of blood samples with the Lineage Cocktail and, whenever applicable, the cells can be simultaneously stained by other monoclonal antibodies conjugated to appropriate fluorochromes. For example, dendritic cells can be distinguished from basophils by positive staining with PE conjugated anti-HLA-DR antibody. Staining whole peripheral blood with mixture of conjugated antibodies is followed by a lysis of red blood cells, wash and subsequent flow cytometry analysis.
Applicable Applications for CD3/CD14/CD16/CD19/CD20/CD56 assay kit
FCM/FACS (Flow Cytometry)
Staining protocol
1. Collect peripheral blood in a sterile tube with an anticoagulant (e.g. Heparin, EDTA).
2. Add 20 ul of the Lineage Cocktail (CD3, CD14, CD16, CD19, CD20, CD56) FITC reagent to a test tube.
3. Whenever applicable, add marker-specific antibody conjugated with appropriate fluorochrome to the test tube.
4. Add 100 ul of blood sample to the tube. Vortex the tube.
5. Incubate the tube for 20-30 minutes at room temperature in the dark.
6. Perform lysis of red cells using lysing solution. It is recommended to use a commercial lysing solution containing paraformaldehyde as a fixative. Follow the instructions of the lysing solution manufacturer.
7. Centrifuge the tube for 5 minutes at 300 g.
8. Remove supernatant and resuspend pellet with 3-4 ml of PBS.
9. Centrifuge the tube for 5 minutes at 300 g.
10. Remove supernatant and resuspend pellet with 0.3-0.5 ml of PBS.
11. Analyze the sample immediately using a flow cytometer or store sample at 2-8 degree C in the dark and analyze within 24 hours provided that cells were fixed.
Preparation and Storage
Store it under sterile conditions at -20 degree C to -80 degree C. It is recommended that the protein be aliquoted for optimal storage. Avoid repeated freeze-thaw cycles.

Application Data

(Figure-3: Separation of human target population cells (red-filled) from basophils (black-dashed) in flow cytometry analysis (surface staining) of human peripheral whole blood stained using Lineage Cocktail FITC (20 ul cocktail/100 ul of peripheral whole blood).)

product-image-AAA78592_AD11.jpg Application Data (Figure-3: Separation of human target population cells (red-filled) from basophils (black-dashed) in flow cytometry analysis (surface staining) of human peripheral whole blood stained using Lineage Cocktail FITC (20 ul cocktail/100 ul of peripheral whole blood).)

FCM/FACS (Flow Cytometry)

(Figure-2: Flow cytometry multicolor surface staining of human peripheral whole blood stained using Lineage Cocktail FITC (20 ul cocktail/100 ul of peripheral whole blood) and anti-human CD203c (NP4D6) APC antibody (10 ul reagent/100 ul of peripheral whole blood).)

product-image-AAA78592_FCM13.jpg FCM/FACS (Flow Cytometry) (Figure-2: Flow cytometry multicolor surface staining of human peripheral whole blood stained using Lineage Cocktail FITC (20 ul cocktail/100 ul of peripheral whole blood) and anti-human CD203c (NP4D6) APC antibody (10 ul reagent/100 ul of peripheral whole blood).)

FCM/FACS (Flow Cytometry)

(Figure-1: Flow cytometry surface staining pattern of human peripheral whole blood stained using Lineage Cocktail FITC (20 ul reagent/100 ul of peripheral whole blood).)

product-image-AAA78592_FCM15.jpg FCM/FACS (Flow Cytometry) (Figure-1: Flow cytometry surface staining pattern of human peripheral whole blood stained using Lineage Cocktail FITC (20 ul reagent/100 ul of peripheral whole blood).)
Product Categories/Family for CD3/CD14/CD16/CD19/CD20/CD56 assay kit

Similar Products

Product Notes

The Human CD3/CD14/CD16/CD19/CD20/CD56 (Catalog #AAA78592) is an Assay Kit and is intended for research purposes only. The product is available for immediate purchase. The AAA78592 Assay Kit recognizes Human CD3/CD14/CD16/CD19/CD20/CD56. AAA Biotech's Lineage Cocktail (CD3/CD14/CD16/CD19/CD20/CD56) can be used in a range of immunoassay formats including, but not limited to, FCM/FACS (Flow Cytometry). Researchers should empirically determine the suitability of the CD3/CD14/CD16/CD19/CD20/CD56 for an application not listed in the data sheet. Researchers commonly develop new applications and it is an integral, important part of the investigative research process. It is sometimes possible for the material contained within the vial of "Lineage Cocktail (CD3/CD14/CD16/CD19/CD20/CD56), Monoclonal Assay Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Submit a Question

Please complete the form below and a representative will contact you as soon as possible.

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.