Intracellular Total ROS Activity Assay Kit

Intracellular Total ROS Activity Assay Kit

Applications
Flow Cytometry, Functional Assay
Synonyms
Intracellular Total ROS Activity; N/A; Intracellular Total ROS Activity Assay Kit; Intracellular Total ROS Activity Assay; Intracellular Total ROS Activity assay kit
Ordering
Sample
Cell culture
Excitation/Emission
490 nm / 520 nm
Applicable Applications for Intracellular Total ROS Activity assay kit
FCM/FACS (Flow Cytometry)
Preparation and Storage
Store total ROS Green and DMSO at < = -20 degree C. Store Assay Buffer at < = 2-8 degree C.
Related Product Information for Intracellular Total ROS Activity assay kit
Background: Reactive oxygen species (ROS) are natural byproducts of the normal metabolism of oxygen and play important roles in cell signaling. However, during oxidative stress-related states, ROS levels can increase dramatically. The accumulation of ROS results in significant damage to cellular structures. The role of oxidative stress in cardiovascular disease, diabetes, osteoporosis, stroke, inflammatory diseases, a number of neurodegenerative diseases and cancer, has been well established. Intracellular Total ROS Activity Assay provides a good screening option for assessing the potency of oxidative stress inhibitor and activator reagents, and will help to determine how oxidative stress modulates varied intracellular pathways. This kit assesses the overall level of intracellular ROS activity, but does not identify the specific reactive oxygen molecule(s) generated by the oxidative stress event. The kit provides all the essential reagents and an easy to follow protocol to assess changes in intracellular ROS levels by flow cytometry. The key reagent in the assay is a proprietary dye called Total ROS Green. This dye quickly penetrates membrane structures and accumulates within the cell. In the presence of ROS, the non-fluorescent Total ROS Green dye molecule is oxidized by all various iterations of ROS molecular forms. In the oxidized state, the Total ROS Green dye molecule acquires fluorescence properties that enable its detection by flow cytometry (Ex/Em: 490 nm/520 nm) as an indicator of the relative level of intracellular ROS activity. This assay is not designed to determine which particular cell pathology triggered the increase in intracellular ROS concentration in the treatment cell populations, or which individual species of reactive oxygen are involved in the cell response. Other testing parameters must be analyzed to establish the specific causation process responsible for the increased intracellular ROS activity levels. Intracellular Total ROS Activity Assay requires minimal procedural steps and hands-on time to complete. Suspension cells or EDTA disassociated adherent cells are stained for 1 hour to pre-load the cells with Total ROS Green quantitation dye. Cells are then treated experimentally. Since the non-internalized dye probe is non-fluorescent, subsequent wash steps are not required, thus simplifying the assay procedure. Following treatment, cells are ready for analysis by flow cytometry. Each kit will enable the assessment of up to 100 samples (0.5 mL each). This assay can be adapted for use with a fluorescence microscope or plate reader equipped with FITC/FAM dye-compatible excitation/emission optics. Use and optimization of these alternative fluorescence analysis methods will require further modification of this flow cytometer based protocol.
Product Categories/Family for Intracellular Total ROS Activity assay kit

Similar Products

Product Notes

The Intracellular Total ROS Activity (Catalog #AAA52759) is an Assay Kit and is intended for research purposes only. The product is available for immediate purchase. AAA Biotech's Intracellular Total ROS Activity can be used in a range of immunoassay formats including, but not limited to, FCM/FACS (Flow Cytometry). Researchers should empirically determine the suitability of the Intracellular Total ROS Activity for an application not listed in the data sheet. Researchers commonly develop new applications and it is an integral, important part of the investigative research process. It is sometimes possible for the material contained within the vial of "Intracellular Total ROS Activity, Assay Kit" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Submit a Question

Please complete the form below and a representative will contact you as soon as possible.

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.