Loading...

Skip to main content
Call us at +1-800-604-9114 for more information about our products or contact us online Need help? +1-800-604-9114 or contact us
product-image-AAA71482_AD13.gif Application Data (Fig.2: SDS-PAGE analysis of purified YD-9H8 monoclonal antibody. Lane 1: molecular weight marker, Lane 2: 2 ?g of purified YD-9H8 antibody. Proteins were separated by SDSPAGE and stained with RAPID StainTM Reagent.)

Rat anti-Human CLAUDIN6/9 Monoclonal Antibody | anti-EPOR antibody

anti-human Claudin 6 and Claudin 9 monoclonal antibody

Gene Names
EPOR; EPO-R
Reactivity
Human
Applications
ELISA, Flow Cytometry, Functional Assay
Purity
Protein G
Synonyms
CLAUDIN6/9, Antibody; anti-human Claudin 6 and Claudin 9 monoclonal antibody; CLDN6; CLDN9; anti-EPOR antibody
Ordering
Host
Rat
Reactivity
Human
Clonality
Monoclonal
Isotype
IgG2b
Clone Number
YD-9H8
Specificity
anti-human Claudin 6 and Claudin 9
Purity/Purification
Protein G
Form/Format
Purified
Sequence Length
508
Applicable Applications for anti-EPOR antibody
ELISA (Competitive ELISA), FCM/FACS (Flow Cytometry)
Buffer
phosphate buffered saline, pH 7.2
Immunogen
genetic immunisation with cDNA encoding human Claudin 9
Selection
based on recognition of the complete native protein expressed on transfected mammalian cells
Immunogen
cDNA
Preparation and Storage
Short term: 2 degree C - 8 degree C; long term: -20 degree C (avoid repeated freezing and thawing)

Application Data

(Fig.2: SDS-PAGE analysis of purified YD-9H8 monoclonal antibody. Lane 1: molecular weight marker, Lane 2: 2 ?g of purified YD-9H8 antibody. Proteins were separated by SDSPAGE and stained with RAPID StainTM Reagent.)

product-image-AAA71482_AD13.gif Application Data (Fig.2: SDS-PAGE analysis of purified YD-9H8 monoclonal antibody. Lane 1: molecular weight marker, Lane 2: 2 ?g of purified YD-9H8 antibody. Proteins were separated by SDSPAGE and stained with RAPID StainTM Reagent.)

Application Data

(Fig.1: GM-1111. BOSC23 cells were transiently transfected with an expression vector encoding either Claudin 9 (red curve), Claudin 6 (green curve) or an irrelevant protein (control transfectant). Binding of YD-9H8 was detected with a PE conjugated secondary antibody. A positive signal was obtained with Claudin 9 and Claudin 6 transfected cells.)

product-image-AAA71482_AD15.gif Application Data (Fig.1: GM-1111. BOSC23 cells were transiently transfected with an expression vector encoding either Claudin 9 (red curve), Claudin 6 (green curve) or an irrelevant protein (control transfectant). Binding of YD-9H8 was detected with a PE conjugated secondary antibody. A positive signal was obtained with Claudin 9 and Claudin 6 transfected cells.)
Related Product Information for anti-EPOR antibody
Background: Claudin 6 and Claudin 9 belong to the claudin family which constitutes a large group of fourtransmembrane domain proteins (1). Claudins are integral tight junction proteins that are responsible for maintaining the integrity of epithelial cell architecture, the control of paracellular transport and cell polarity. The expression pattern of claudins is tissue specific, most tissues express multiple claudins, which can interact in both homotypic and heterotypic fashion to form the tight junction strands (2). Several claudin proteins have been shown to be abnormally expressed in cancers. The differential expression of these proteins between tumour and normal cells, in addition to their membrane localisation, makes them prime candidates for cancer therapy (2). Members of the claudin family, including Claudin 6 and 9 are expressed in the liver and play a critical role in Hepatitis C Infection. They function as coreceptors in HCV entry and assume a role in HCV dissemination, replication and pathogenesis (3).
References
Kazumasa M, Mikio F, Kazushi F, Shoichiro T (1999). Claudin multigene family encoding fourtransmembrane domain protein components of tight junction strands. Proc Natl Acad Sci U S A. 19; 96(2): 511–516.
Morin PJ (2005). Claudin proteins in human cancer: promising new targets for diagnosis and therapy. Cancer Res. 1;65(21):9603-6.
Zheng A, Yuan F, Li Y, Zhu F, Hou P, Li J, Song X, Ding M, Deng H (2007). Claudin-6 and claudin-9 function as additional coreceptors for hepatitis C virus. J Virol. 81(22):12465-71.
Fofana I, Zona L, Thumann C, Heydmann L, Durand SC, Lupberger J, Blum HE, Pessaux P, Gondeau C, Reynolds GM, McKeating JA, Grunert F, Thompson J, Zeisel MB, Baumert TF (2013). Functional analysis of claudin-6 and claudin-9 as entry factors for hepatitis C virus infection of human hepatocytes by using monoclonal antibodies. J Virol. 87(18):10405-10

NCBI and Uniprot Product Information

NCBI GI #
NCBI GeneID
NCBI Accession #
NCBI GenBank Nucleotide #
UniProt Accession #
Molecular Weight
35,809 Da
NCBI Official Full Name
erythropoietin receptor
NCBI Official Synonym Full Names
erythropoietin receptor
NCBI Official Symbol
EPOR
NCBI Official Synonym Symbols
EPO-R
NCBI Protein Information
erythropoietin receptor
UniProt Gene Name
EPOR
UniProt Synonym Gene Names
EPO-R
UniProt Entry Name
EPOR_HUMAN

Similar Products

Product Notes

The EPOR epor (Catalog #AAA71482) is an Antibody produced from Rat and is intended for research purposes only. The product is available for immediate purchase. The anti-human Claudin 6 and Claudin 9 monoclonal antibody reacts with Human and may cross-react with other species as described in the data sheet. AAA Biotech's CLAUDIN6/9 can be used in a range of immunoassay formats including, but not limited to, ELISA (Competitive ELISA), FCM/FACS (Flow Cytometry). Researchers should empirically determine the suitability of the EPOR epor for an application not listed in the data sheet. Researchers commonly develop new applications and it is an integral, important part of the investigative research process. It is sometimes possible for the material contained within the vial of "CLAUDIN6/9, Monoclonal Antibody" to become dispersed throughout the inside of the vial, particularly around the seal of said vial, during shipment and storage. We always suggest centrifuging these vials to consolidate all of the liquid away from the lid and to the bottom of the vial prior to opening. Please be advised that certain products may require dry ice for shipping and that, if this is the case, an additional dry ice fee may also be required.

Precautions

All products in the AAA Biotech catalog are strictly for research-use only, and are absolutely not suitable for use in any sort of medical, therapeutic, prophylactic, in-vivo, or diagnostic capacity. By purchasing a product from AAA Biotech, you are explicitly certifying that said products will be properly tested and used in line with industry standard. AAA Biotech and its authorized distribution partners reserve the right to refuse to fulfill any order if we have any indication that a purchaser may be intending to use a product outside of our accepted criteria.

Disclaimer

Though we do strive to guarantee the information represented in this datasheet, AAA Biotech cannot be held responsible for any oversights or imprecisions. AAA Biotech reserves the right to adjust any aspect of this datasheet at any time and without notice. It is the responsibility of the customer to inform AAA Biotech of any product performance issues observed or experienced within 30 days of receipt of said product. To see additional details on this or any of our other policies, please see our Terms & Conditions page.

Item has been added to Shopping Cart

If you are ready to order, navigate to Shopping Cart and get ready to checkout.

Submit a Question

Please complete the form below and a representative will contact you as soon as possible.

Request more Information

Please complete the form below and a representative will contact you as soon as possible.

Request a Manual

Please complete the form below and a representative will contact you as soon as possible.

Request a Quote

Please complete the form below and a representative will contact you as soon as possible.